02 · Module Tiers

The two rbAmp module lines, BASIC and STANDARD (STD), and where energy is computed on each.

rbAmp ships in two module lines: BASIC and STANDARD (STD). Each tier is a complete combination of hardware revision and firmware build, not just a flag in the firmware. Moving between tiers requires physically swapping the module, not a firmware upgrade.

The ESPHome component works with both module lines from one YAML: the schema is shared, and the component identifies the connected module line (BASIC or STANDARD (STD)) automatically at boot. The differences are what data the module actually exports and which YAML keys are meaningful on each module line.


Tiers

BASIC — entry level

The firmware keeps unidirectional consumption metering: the average active power over a period can never be negative — reverse segments within the window are zeroed before integration. Behaviorally this resembles a classic mechanical disc meter.

  • Energy is integrated on the ESP32 from the period-average power the module returns after each snapshot, and saved to the ESP32 flash (NVS).
  • The energy_exported sensor exists in the YAML schema (for config compatibility), but on BASIC it always publishes 0.
  • The grand-total energy sensors (energy_total, energy_exported_total, energy_net, reactive_energy, reactive_energy_exported) validate but never publish on BASIC.
  • Typical applications: apartments without on-site generation, sub-metering of specific loads (water heaters, motors, household appliances, HVAC).

STANDARD (STD) — bidirectional, on-device energy

STANDARD (STD) is the current module line. It measures import and export separately and keeps its own cumulative energy counters inside the module.

  • Same YAML. The component recognises a STANDARD (STD) module at boot and takes the channel count, variant and available features from the module. You do not set a tier and you do not need topology:.
  • Energy from the module's counters. The component accumulates the module's counters instead of integrating power itself, so totals survive restarts of both the ESP32 and the module, stay monotonic across module restarts and counter resets, and do not drift. The values are additionally saved to the ESP32 flash (NVS) every 5 minutes and on a clean shutdown (reboot / OTA).
  • New sensors: energy_total, energy_exported_total, energy_net (import − export, may decrease), reactive_energy, reactive_energy_exported — grand totals over all channels; on three-voltage variants also voltage_angle_b, voltage_angle_c and phase_sequence.
  • Per-channel energy and energy_exported (with bidirectional: true) come from the same counters.
  • start_current_ua: sets a starting current below which a channel counts no energy, so noise at no load does not creep into the counters.
  • Typical applications: homes with solar/wind generation, battery storage, EV chargers, any installation where import and export must be metered separately, and installations where energy totals must survive restarts.

On an STD module energy comes from the module's own counters; latch_interval applies only to BASIC.

Keys that exist only for the BASIC module line (fleet_gc_enable:, group_id:, broadcast_latch:, latch_interval: for the master-side energy path) are ignored on a STANDARD module with a log line.

Energy accounting on BASIC (master integrates the period average power) versus STANDARD (master reads the module's cumulative counters).


Capability Matrix

Capability BASIC STANDARD
RMS voltage yes yes
RMS current (1..3 channels, more on higher-channel variants) yes yes
Active power (signed float) yes yes
Power factor yes yes
Reactive power (read from the module, channels 0..2; unsigned, computed as √(S² − P²), includes distortion; no accuracy stated) yes yes
Apparent power (CH0 only) yes (U × I[0], computed on the ESP32) yes (from the module)
Line frequency yes yes
energy sensor (import Wh), saved to NVS yes (integrated on the ESP32) yes (from on-device counters)
energy_exported sensor (needs bidirectional: true) always 0 yes
Energy survives ESP32 and module restarts ESP32 only yes
Grand totals: energy_total, energy_exported_total, energy_net no yes
Reactive energy: reactive_energy, reactive_energy_exported no yes
start_current_ua: no yes
voltage_angle_b/_c, phase_sequence (three-voltage variants) no yes
Per-channel ct_models: yes only if the module stores per-channel models; otherwise refused with a log line
fleet_gc_enable: / group_id: general-call sync yes (v1.3+ firmware) ignored

The component reads only what sensors are declared for — an undeclared register is never requested.


YAML Keys by Tier

bidirectional: (default false)

Enables the per-channel export-energy sensors (energy_exported, energy_exported_1, energy_exported_2).

yaml
rbamp:
  id: solar_meter
  address: 0x51
  bidirectional: true   # meaningful on STANDARD; on BASIC the export sensors read 0

On STANDARD the export energy is taken from the module's counters. On BASIC the key is accepted by the schema without error, but energy_exported always returns 0. The grand-total sensors energy_exported_total and energy_net do not need this key.

sensor_class: — pin the sensor family

yaml
rbamp:
  id: meter1
  sensor_class: SCT_013   # default SCT_013

Accepted on both module lines. On firmware v1.2+ the value is written to flash and becomes a precondition for writing the CT model: the module refuses to write the model if the class is not set. A value the module already has is not written again.

Enum values: SCT_013 (split-core SCT-013 clamps, default), WIRED_CT and BUILTIN_CT (modules supplied calibrated together with their own fitted sensor). On such a factory-paired module a class or model change from YAML is refused with a log line, to protect the individual calibration.

ct_model: / ct_models: — CT clamp model

A single global profile for all channels:

yaml
rbamp:
  id: meter1
  ct_model: SCT_013_030   # all channels — SCT-013-030

Or a per-channel profile (for UI3 with mixed clamps):

yaml
rbamp:
  id: meter_ui3
  ct_models: [SCT_013_005, SCT_013_030, SCT_013_020]

Accepted on both module lines, mutually exclusive. On firmware v1.2+ the module automatically loads the factory coefficients for the selected model — no additional calibration steps are required. On earlier firmware the value is stored as a model marker.

  • Switching the SCT rating keeps the factory accuracy: the component completes the switch (a module restart in the flow is normal on firmware up to 1.4.19; newer firmware corrects on the module) and scales readings to the selected sensor.
  • Write guards: an equal value is not written; on a factory-paired module the change is refused with a log line. ct_model_force: true (service option, only valid together with ct_model: / ct_models:) overrides this deliberately.
  • Per-channel ct_models: on a STANDARD module needs the module to store per-channel models; otherwise the component refuses loudly (warning, keys ignored) — use ct_model:.

For more on selecting a model, see 03_sensor_selection.md.

new_address: — one-time I²C address provisioning

yaml
rbamp:
  id: meter1
  address: 0x50
  new_address: 0x51   # one-shot; remove after a successful boot

Accepted on both module lines. On firmware v1.3+ the address change is production-OK — the component uses a two-phase commit protocol (stage → arm → commit → reboot) with no special mode required. On legacy firmware (v1.0-v1.2) the single-phase fallback requires factory-provisioning mode; consult the module documentation or your supplier for the procedure to enable it. Factory-provisioning mode is still required on all firmware versions for calibration (saveGains) and factory-reset operations.

Execution flow over a single boot: the component polls the current address, writes the new address and saves it to flash, resets the module, and verifies the response at the new address. After success, update the YAML to address: 0x51 and remove new_address:. If the component finds that the old address is silent while the new one responds, it adapts automatically with a warning in the log (in case a previous boot already applied the change).

fleet_gc_enable: / group_id: — synchronous snapshot for a multi-module bus

yaml
rbamp:
  - id: meter1
    fleet_gc_enable: true   # v1.3 production path — recommended
    group_id: 1             # cluster id (modules in the same group snapshot together)

When enabled, the component sends a 5-byte general-call frame to the I²C broadcast address — synchronizing the period snapshot across all modules in the same group_id in a single transaction.

On v1.3 BASIC firmware the general-call snapshot is opt-in and capability-gated. The component checks at boot whether the firmware advertises it and enables the path automatically when both the YAML key and the firmware agree. On legacy firmware (v1.0..v1.2) it is not advertised; the component falls back to a sequential snapshot for each module individually and logs an informational line. On a STANDARD module these keys are ignored with a log line.

The legacy broadcast_latch: key is still accepted by the schema for backward compatibility but has no effect. Use fleet_gc_enable: + group_id:.

The skew between modules on a 50 kHz bus is on the order of ~540 µs × N, which is less than 0.003% of a 60-second period. On daily HA totals this unevenness is imperceptible.

topology: — topology hint

yaml
rbamp:
  id: meter1
  topology: SINGLE      # SINGLE / SPLIT_PHASE / THREE_PHASE

Optional and not needed on STANDARD modules, where the channel count and variant come from the module itself. On BASIC modules the component infers the channel count from the declared sensor slots (if current_1 is declared, there are at least 2 channels). The key is cosmetic and goes into the dump_config log line.

drdy_pin: — optional data-ready interrupt

yaml
rbamp:
  id: meter1
  drdy_pin: GPIO15

Accepted on both module lines. Connects to the module's optional open-drain DRDY output. The pin is configured and logged, but the instantaneous registers are polled on update_interval regardless. With a typical update_interval: 60s the key can be omitted.

Requires a 10 kΩ pull-up on the master GPIO to 3.3 V (the output is open-drain; there is no internal pull-up on the module side). See 04_hardware.md.


Summary Table — YAML Key × Module Line

YAML key BASIC STANDARD Notes
address: yes yes —
update_interval: yes yes Minimum 1s
latch_interval: yes n/a Decouples the snapshot/energy cadence from the read cadence; STANDARD reads its counters on every update()
drdy_pin: yes yes Optional, needs a 10 kΩ pull-up; not used as a read trigger
topology: yes not needed Informational hint
sensor_class: yes yes Not rewritten when equal; refused on factory-paired modules
ct_model: / ct_models: yes yes Mutually exclusive; per-channel list on STANDARD needs a module that stores it
ct_model_force: yes yes Service option; schema requires a model key
bidirectional: accepted (export reads 0) works Needed for energy_exported* per-channel sensors
start_current_ua: ignored with a warning works 0 or 10..2540 in steps of 10
new_address: yes yes Production-OK on v1.3+ BASIC firmware; one-shot
fleet_gc_enable: / group_id: / broadcast_latch: yes ignored General-call sync is a BASIC-line feature
energy_exported sensor always 0 works Needs bidirectional: true
energy_total, energy_exported_total, energy_net, reactive_energy[_exported] never publish works Grand totals from on-device counters
voltage_angle_b/_c, phase_sequence never publish works on three-voltage variants with a firmware that provides them See 09 §2.2–2.3
Phased sensors (voltage_a/b/c, current_a/b/c, …) no values publish for the channels the module reports Details in 09 §2.2

What's Next


Source & issues: rb-amp/rbamp-esphome · this page in the repo: docs/02_tiers.md (v1.9.1)