v1.9.0 — 2026-10-21

Public releases resume with this version; intermediate versions were released internally only.

SCT rating switch without losing factory accuracy (8-bit line), plus the guard releases 1.8.x folded into this public release.

Added

  • SCT-013-060 and -100 are accepted (they were refused client-side as reserved); sensor-model clip limits updated to measured values.
  • SCT rating-switch correction (modules with the SCT-013 sensor class, firmware ≤ 1.4.19). Every SCT module is factory-calibrated with the -030 sensor; selecting another ct_model: used to leave current/power/energy on the -030 scale. The component now completes the model write with the module restart the procedure requires (save → reset → re-probe with a UID check), reads the gain the module actually applies and scales current, active/reactive power and the energy integration to the selected sensor's rating — the per-unit factory trim is preserved. Voltage and power factor are not affected. A module restart (own or external) is detected and the correction recomputes automatically. If the applied gain is outside ±5 % of the calibration-model value, the component warns and does not scale. No YAML change needed.
  • Firmware 1.4.20+ performs the rating switch on-device and advertises it — the component then detects it and leaves the readings untouched (plain model write, no restart).
  • Host test for the correction decision logic: tests/host/test_sct_rating.cpp (plain g++, no framework).

v1.8.1 — 2026-10-18

Fixed

  • Factory-calibration protection for sensor_class: / ct_model: (8-bit line). The firmware clears the channel models and linearity shapes on any sensor-class write (even an unchanged value) and re-applies the generic preset on any CT-model write — the component now never writes a value the device already has, and refuses class/model changes from YAML on a module calibrated as a pair with its fitted sensor (classes WIRED_CT / BUILTIN_CT), with an explicit log line. New service option ct_model_force: true deliberately re-applies the preset; the schema rejects it without a model key so it cannot sit armed in YAML.
  • Out-of-bounds read on 5/7-channel modules (UI5/UI7): the boot restore-publish loop indexed the 3-slot export arrays up to channel 6 and could publish a garbage value into the adjacent sensor. Fixed with the same channel gate every other export site already had; array sizes are now pinned by compile-time asserts.
  • Documentation/comments aligned to the family measurement window of 100 ms (firmware v1.2+; 200 ms only on older images).

v1.8.0 — 2026-10-17

On-device cumulative energy for the 16-bit line.

Added

  • Energy from on-device counters (16-bit-map modules advertising them in the capability bitmap): the component stops integrating Wh itself and accumulates the module's own counters — totals survive restarts of both the ESP32 and the module, with no integration drift. Micro-resolution (µWh/µvarh) on firmware that publishes it, automatic coarse fallback otherwise. Each snapshot is read in one coherent I²C transaction, and the published sums stay monotonic across module restarts and counter resets.
  • New grand-total sensors: energy_total, energy_exported_total, energy_net (import − export, may decrease), reactive_energy, reactive_energy_exported.
  • start_current_ua: config key (0 = off, 10..2540 in 10 µA steps): below this current a channel does not accumulate energy — at no load the measured power is noise of either sign that would otherwise creep into both import and export. Readings are unaffected. Schema-validated; persisted on the device with a verified save.
  • Three-phase surfaces: voltage_angle_b / voltage_angle_c (degrees, relative to phase A) and phase_sequence (1 forward · 2 reverse · 3 abnormal), published on firmware that provides them; "unknown" otherwise.
  • Lambda accessors: get_std_image_version(), get_phase_sequence_str(), read_start_current_ua().

v1.7.0 — 2026-09-30

Support for the new 16-bit register-map module line, autodetected on the same YAML.

Added

  • Dual-line support: an identity probe at boot detects 16-bit-map modules and switches the transport (big-endian pointer, auto-increment burst reads). Channel counts, variant and capabilities come from the device's discovery block — topology: and YAML slot counts are no longer needed to size the entity surface. 8-bit modules behave exactly as before.
  • Realtime sensors on the 16-bit line are published from the device's fixed-point registers; energy uses the device's atomic latch snapshots with master-clock integration and the same NVS persistence.
  • Config keys (sensor_class:, ct_model:, new_address:) work on the 16-bit line through its staged config block with a synchronously verified save. Per-channel ct_models: on this line requires the device to advertise persistent per-channel maps (capability bit); the component refuses loudly instead of losing the write silently.
  • Automatic recovery after a module restart mid-run: the component detects the dropped accumulator arm, re-arms and re-primes, skipping one window instead of silently stopping energy accumulation.
  • NVS flush on clean shutdown (reboot/OTA no longer loses up to the last save interval of energy).

v1.6.0 — 2026-09-04

Per-channel ct_models: for all channels (0..15), sensor-model registry, and persist fix. Firmware: v1.4.18+ required for senior channels 3+.


v1.5.0 — 2026-08 (internal only)

Added

  • UI5/UI7 senior-SKU support: channels 3–6 read through the channel-access window (realtime metrics and per-channel period energy), NVS energy slots extended to 7 channels.

Added

  • Per-channel CT models on all channels. ct_models: in YAML now accepts up to 16 entries. Module variant detection determines how many are applied; extra entries produce a warning, not a failure.
  • Sensor-model registry — the model list comes from a single registry. The two hardcoded lists (CT_MODELS dict + CT_MODEL_ALLOWED_PER_CLASS) are replaced by a single registry lookup. Adding a new CT SKU is now a registry edit — no library release needed.

Fixed

  • v1.6.0 adds SAVE after the apply cycle. Prior versions used a factory-gated persist path for CT model and sensor class — on a production module the binding applied to RAM but was lost on reboot. v1.6.0 persists via CMD_SAVE_USER_CONFIG (ungated). Users of prior versions in production silently lost the CT model binding on every reboot — update before shipping devices.

v1.4.0

Senior-SKU detection (5/7-channel variants), channel-access window for realtime metrics, and the optional latch_interval: key that decouples the latch/energy cadence from the read cadence (update_interval:). Energy stays monotonic and accurate: integration uses the actual wall-clock time between latch events.


v1.3.0

Initial public release. Multi-channel and multi-module fleet with general-call latch synchronization (fleet_gc_enable: + group_id:), two-phase address commit (production-OK, no factory-provisioning mode), read-compare-write boot writeback, capability-gated feature detection, identity surface for lambdas (get_variant_str(), get_uid_hex(), ...), NVS energy persistence.


Deprecation policy

What the component promises not to break without warning, and what it may:

Surface Stability What we promise
YAML keys of the rbamp: block Stable Removal or renaming is only possible on a major bump. A deprecation warning appears in the log before removal. broadcast_latch: and topology: are kept in the schema for backward compatibility.
YAML keys of sensor.platform: rbamp (slots) Stable Same rules. The names voltage/current/power/energy/frequency/power_factor are fixed as a contract with the HA Energy dashboard.
The set of HA entities and their device_class / state_class Stable We will not change it without an announcement; it affects entity_id in HA.
Lambda-accessible RbAmpComponent::* methods Unstable These may change in minor releases. If you write lambda actions against them, pin the component version (ref: in external_components:).
NVS structure format Versioned Changes come with a bump of the layout version — old data is discarded, never misread.
Names and behavior of the i2c: block External This is ESPHome core, not ours — follow the upstream policy.

Upgrade guide

To v1.9.0 (from any earlier version)

  1. Set ref: v1.9.0 in external_components:.
  2. No YAML change is required. The same YAML works for both module lines; the component identifies the connected module at boot. topology: is not needed.
  3. If you want energy totals over all channels on a STANDARD (STD) module, add energy_total / energy_exported_total / energy_net (see 09 §2.3).
  4. If your YAML sets sensor_class: or ct_model: on a module supplied calibrated together with its fitted sensor, the component now refuses the change and logs it. Remove those keys for such modules.
  5. If you switched the SCT rating via ct_model:, readings now stay accurate; a module restart during the switch is normal on firmware up to 1.4.19.
  6. ct_model_force: true is a service option only; the schema rejects it without ct_model: / ct_models:.
  7. Per-channel NVS energy values are preserved on upgrade; the new grand-total sensors start from 0 at first boot and then accumulate (their NVS slot is separate).

From v1.3 / v1.4

  1. Update ref:.
  2. SCT_013_100 (code 5) and SCT_013_060 (code 7) are accepted.
  3. Optionally add fleet_gc_enable: / group_id: for synchronized snapshots in a multi-module deployment (BASIC modules).

Source & issues: rb-amp/rbamp-esphome · this page in the repo: docs/11_changelog.md (v1.9.1)