02 · Module Lines

The BASIC and STANDARD (STD) module lines and what each provides.


What a Module Line Is

rbAmp modules come in two module lines: BASIC and STANDARD (STD). A module line is a complete bundle of a hardware revision and firmware, not a software flag. Moving between module lines requires a physical SKU change, not a firmware update.

From the package and user-code perspective: one RbAmp class serves every module line, and the common readers (voltage, current, power, power_factor, frequency) work on all of them. The module line is detected automatically at begin(). STANDARD (STD) modules additionally expose the STD-only calls (on-device energy and so on, see below); calling one of those on a BASIC module raises RbAmpNotSupportedError.


Current State

BASIC and STANDARD modules are supported by this library (STANDARD from 1.6.0).

Module line Shipping
BASIC ✅ yes
STANDARD (STD) ✅ yes (supported by this library from 1.6.0)

BASIC — Entry-Level Consumption-Metering Module Line

Hardware

A cost-optimized analog path suited to typical household loads. The module includes an isolated analog front-end, an on-board power regulator, and factory calibration in flash memory.

Firmware Behavior

The logic of a classic mechanical disc meter — the count only goes forward; export to the grid is not subtracted.

The three "layers" of active-power values behave differently:

Signal Meaning Behavior on BASIC
dev.power[ch] / dev.read_power(ch) instantaneous RT power, ~100 ms update signed — a negative value is visible in real time (export)
snap.avg_p[ch] (from dev.read_period_snapshot()) average power over the period each 100 ms average-P window is clamped to max(P, 0) before being added to the period accumulator
dev.energy.wh(ch) accumulated Wh by the package monotonic — consumption only; export is not counted

In other words: the user sees export in the RT reading, but it is not present in the package's Wh counter on BASIC.

Typical Applications

  • Households without their own generation (no solar panels, wind turbines, battery systems)
  • Submetering of purely consuming loads (water heaters, motors, home appliances)
  • Building consumption monitoring where bidirectional metering is not required

Bidirectional Metering on BASIC (Master-Side)

BASIC counts consumption only on the module with export handled on the master, while STD keeps cumulative counters on the device.

If you need to track export to the grid separately on a BASIC module, do it on the master side. The RT power dev.power[0] is signed (or the equivalent method dev.read_power(0)), so:

python
import time
from rbamp import RbAmp, RbAmpIOError
def bidirectional_loop(dev):
    consume_wh = 0.0
    export_wh  = 0.0
    t_prev = time.monotonic()
    while True:
        # Sample RT power at 10 Hz — matches the firmware-commit
        # cadence (100 ms per channel). Faster yields empty repeated
        # reads; slower loses resolution on sharp load transitions.
        time.sleep(0.1)
        t_now = time.monotonic()
        dt_s  = t_now - t_prev
        t_prev = t_now
        try:
            p = dev.read_power(0)
        except RbAmpIOError:
            continue
        dwh = p * dt_s / 3600.0
        if p >= 0.0:
            consume_wh += dwh
        else:
            export_wh  += -dwh

On MicroPython, replace time.monotonic() with time.ticks_ms() / time.ticks_diff() (more accurate and cheap on RAM on embedded platforms) and time.sleep(0.1) with time.sleep_ms(100). On CPython, no changes.

A complete working example of the pattern is in 06_examples.md, the "Master-side bidirectional metering" scenario, as well as the source files examples_upy/07_bidirectional_energy.py and examples_cpython/05_bidirectional_energy.py.


STANDARD (STD) — Shipping Module Line

STANDARD modules are a shipping module line that this library supports from version 1.6.0. They use a different (16-bit) register map from BASIC; the library hides the difference — the same RbAmp class, the same I²C wiring and address, and the same common readers.

What the library adds on an STD module:

  • On-device energy: dev.read_std_energy() returns the module's own lifetime counters — active import / export / net and reactive energy, at Wh, mWh and µWh resolution, with per-channel figures. RbAmp.std_energy_delta(prev, now) gives the energy used between two readings and is safe across a power cut. You do not integrate power on the master for these counters.
  • Period metering: read_period_snapshot() and the other period calls work as on BASIC. begin() picks the source — the module's energy counters (the period is the difference of two readings; no latch command is sent) or, on a module with latch banks only, latch bank 0. The energy is net (export subtracts).
  • Latch banks (modules that report them): dev.std_arm_banks(mask), dev.std_latch(bank), dev.std_read_latch(bank), RbAmp.std_latch_wh(snap, dt_ms).
  • Multi-phase helpers: dev.read_voltage_angle(phase), dev.read_phase_sequence(), dev.read_reactive(ch) (STD only; on BASIC, reactive power is not exposed by this library), dev.read_apparent(ch).
  • Starting current: dev.get_start_current() / dev.set_start_current(µA) + dev.save_config().
  • Full blocks: dev.read_std_voltage(), read_std_channel(), read_std_totals(), read_std_config(), read_std_health(), dev.set_time().

Notes:

  • Some STD calls need a recent enough module image (micro-unit energy counters, voltage angles, starting current). If the module does not provide one, the call raises RbAmpNotSupportedError ("not available").
  • Use dev.is_std to branch in application code.
  • Sensor-class and CT-model configuration, reset and address change, the identity registers, the error / event channel, the fleet helpers and wait_ready() are BASIC only; on an STD module they raise RbAmpNotSupportedError.
  • On-device energy, angle and starting-current features are validated on CPython (smbus2). The MicroPython 16-bit path is implemented but is not yet hardware-validated — prefer CPython for these features until a release note says otherwise.

Full signatures: 09 · API Reference.


How to Detect the Module Line at Runtime

How to tell at runtime whether the connected module is a BASIC or a STANDARD (STD) module.

In the current firmware there is no explicit "module line" register. Indirect indicators are available through handle properties:

python
# Firmware version — opaque byte
fw = dev.firmware_version
# Presence of a voltage sensor (UI* variants vs I*-only)
voltage_hw = dev.has_voltage_hw
# Number of current channels (1 / 2 / 3 on BASIC; 5 / 7 on UI5 / UI7)
channels = dev.channels
# BASIC variant byte (1=UI1, 2=UI2, 3=UI3, 4=I1, 5=I2, 6=I3, 7=UI5, 8=UI7)
variant = dev.read_variant()
# Module line: True on an STD module (detected in begin())
is_std = dev.is_std

Note: dev.is_std tells you the module line (STD vs BASIC). The other indicators (firmware version, channel count, presence of a voltage sensor, variant) describe the module but do not identify the module line. dev.read_variant() is the BASIC variant byte; use the SKU label on the module enclosure as the source of truth for the product.


Where Module-Line-Dependent Places Are Marked in the Documentation

In the package text and canonical documentation, module-line-dependent features are marked explicitly, for example:

STD only — this call is not available on a BASIC module.

Or, conversely, BASIC-specific behavior:

BASIC: the dev.energy.wh(ch) counter is monotonic — export to the grid is not counted. For bidirectional metering, see the "Master-side bidirectional metering" scenario in 06_examples.md, or use a STANDARD module, where the period energy is net and dev.read_std_energy() has separate import and export counters.


What's Next


Source & issues: rb-amp/rbamp-python · this page in the repo: docs/02_tiers.md (v1.6.1)