What a module line is

rbAmp modules come in module lines: BASIC and STANDARD (STD). A module line is a complete bundle of hardware revision and firmware, not a software flag. Moving between lines requires a physical SKU change, not a firmware update.

The BASIC and STANDARD (STD) module lines side by side.

From the component and user-code perspective: one handle and one rbamp_* API serve both shipping module lines. rbamp_begin() detects whether the module behind the handle is a BASIC or an STD module (rbamp_line()), and the calls that exist on only one of them return ESP_ERR_NOT_SUPPORTED on the other. The differences show up in what values the module returns, in the extra quantities the STD module measures, and in how the firmware treats the data (in particular — export to the grid).


Current status

BASIC and STANDARD (STD) modules are shipping and are both supported by this component (version 1.7.3).

Module line Status in this component
BASIC ✅ shipping — RBAMP_LINE_BASIC
STANDARD (STD) ✅ shipping — RBAMP_LINE_STD

BASIC — entry-level consumption-metering module line

Hardware

A cost-optimized analog path suited to typical household loads. The module includes an isolated analog front-end, an on-board power regulator, and factory calibration stored in flash.

Firmware behavior

The logic of a classic mechanical disc meter — counting only goes forward, export to the grid is not subtracted.

The three "layers" of active-power values behave differently:

Signal Meaning Behavior on BASIC
rbamp_read_power(dev, ch, &p) instantaneous RT power, updated every ~100 ms signed — a negative value is visible in real time (export)
snap.avg_p[ch] (inside rbamp_read_period_snapshot) average power over the period each 100 ms average-P window is clamped to max(P, 0) before being added to the period accumulator
rbamp_energy_wh(dev, ch) Wh accumulated by the component monotonic — consumption only, export is not counted

In other words: the user sees export in the RT reading, but the component's Wh counter on BASIC does not include it.

Typical applications

  • Households without their own generation (no solar panels, wind turbines, battery systems)
  • Submeters for purely consuming loads (water heaters, motors, household appliances)
  • Building consumption monitoring where bidirectional metering is not required

Bidirectional metering on BASIC (master-side)

How energy is produced on a BASIC module (integrated on the master) and on a STANDARD (STD) module (on-device counters). If you need to track export to the grid separately on a BASIC module, do it on the master side. The RT power rbamp_read_power(dev, 0, &p) is signed, so:

c
#include "esp_timer.h"
#include "freertos/FreeRTOS.h"
#include "freertos/task.h"
static double consume_wh = 0.0;
static double export_wh  = 0.0;
void bidirectional_loop(rbamp_handle_t dev) {
    int64_t t_prev_us = esp_timer_get_time();
    while (1) {
        /* Sample RT power at 10 Hz. Slower polling loses resolution
         * on sharp load transitions; faster adds little for typical
         * mixed loads with an inverter. */
        vTaskDelay(pdMS_TO_TICKS(100));
        int64_t t_now_us = esp_timer_get_time();
        double  dt_s     = (double)(t_now_us - t_prev_us) / 1e6;
        t_prev_us = t_now_us;
        float p;
        if (rbamp_read_power(dev, 0, &p) != ESP_OK) continue;
        double dwh = (double)p * dt_s / 3600.0;
        if (p >= 0.0f) consume_wh += dwh;
        else           export_wh  += -dwh;
    }
}

A complete working example of the pattern is in 06_examples.md, the "Master-side bidirectional metering" scenario.


STANDARD (STD) — the extended-measurement module line

STD modules are supported by the same rbamp_* API; rbamp_begin() detects them. On top of what BASIC offers, an STD module provides:

  • Signed energy. Import and export are separate magnitudes, and the module keeps persisted life-time counters (Wh / varh, plus finer resolutions on newer firmware). Export is not clamped away: a period's energy is the difference of two counter readings (rbamp_std_read_energy() / rbamp_std_energy_delta()), and rbamp_energy_wh() carries a signed net value on such modules.
  • More quantities: reactive power and apparent power per channel (rbamp_read_reactive_power(), rbamp_read_apparent_power(), rbamp_std_read_channel()), per-phase and grand totals, and — once harmonics extraction is switched on — THD and displacement power factor. Three-phase modules also report the voltage phase angles and the phase sequence.
  • Period mechanisms: snapshot banks (eight independent, master-timed periods) on modules that have them, or counter differences on modules that keep energy on the device. The mechanism is chosen at rbamp_begin() (rbamp_std_info_t.period_source).
  • CT model is a label only. On an STD module the CT model is a label only and sets no gain.
  • Module clock, on-device history and an event log, health and diagnostics, firmware update over I²C, a device certificate and attestation.

All of this is documented in 09 · API Reference, chapter "STD line". A working example is examples/std_meter/ (see 06 · Examples, Scenario 18).

Behaviour that differs from BASIC

Topic BASIC STD
Export in rbamp_energy_wh() not counted (monotonic, consumption only) signed — net of import and export
Reactive / apparent power, THD not available — on BASIC, reactive power is not exposed by this library (ESP_ERR_NOT_SUPPORTED) available
Period source snapshot of the period accumulator snapshot banks, or counter differences
Module clock none set it with rbamp_std_set_time() after every module reset
rbamp_factory_reset() supported ESP_ERR_NOT_SUPPORTED
Digest (rbamp_read_digest()) supported on firmware with the capability ESP_ERR_NOT_SUPPORTED
Period calls on a module with neither snapshot banks nor counters — ESP_ERR_NOT_SUPPORTED

Typical applications

  • Homes with rooftop solar generation, wind turbines or batteries
  • Regenerative loads, V2G electric-vehicle charging
  • Installations that need reactive power, power factor and harmonics in addition to active power

How to detect the module line at runtime

Flowchart for finding out whether you own a BASIC or a STANDARD (STD) module. The product line is detected for you by rbamp_begin():

c
/* BASIC or STD — available after rbamp_begin() */
rbamp_line_t line = rbamp_line(dev);    /* RBAMP_LINE_BASIC / RBAMP_LINE_STD */
/* Full SKU — cached by rbamp_begin(), no bus traffic */
rbamp_variant_t variant = rbamp_variant(dev);   /* UI1 / UI2 / ... / I3 / UI5 / UI7 */
/* Voltage-sensing presence (UI* variants vs I*-only) */
bool voltage_hw = rbamp_has_voltage_hw(dev);
/* Number of current channels (1 / 2 / 3 / 5 / 7) */
uint8_t channels = rbamp_channels(dev);
/* Firmware: BASIC — REG_VERSION byte; STD — register-map version */
uint8_t fw = rbamp_firmware_version(dev);
/* STD only: identity, capabilities and the period mechanism */
rbamp_std_info_t info;
if (rbamp_line(dev) == RBAMP_LINE_STD && rbamp_std_info(dev, &info) == ESP_OK) {
    /* info.capabilities, info.n_voltage, info.n_current, info.period_source */
}

Note: rbamp_line() tells BASIC from STD. Use the SKU label on the module enclosure as the source of truth for the exact product.


Where line-dependent details are marked in the docs

In the component text and the canonical documentation, line-dependent features are marked explicitly, for example:

STD only — this function is not available on the BASIC module (ESP_ERR_NOT_SUPPORTED).

Or, conversely, BASIC-specific behavior:

BASIC: the rbamp_energy_wh(dev, ch) counter is monotonic — export to the grid is not counted. For bidirectional metering, see the "Master-side bidirectional metering" scenario in 06_examples.md, or use an STD module.


What's next


Source & issues: rb-amp/rbamp-esp-idf · this page in the repo: docs/02_tiers.md (v1.7.3)