01 · Overview


What rbAmp is

rbAmp is a compact hardware module for precision measurement of AC mains parameters over the I²C interface. It is built around a microcontroller with an integrated isolated analog front-end and factory calibration stored in flash.

Overview of how the application, the library, the I2C bus and the rbAmp modules fit together.


The library's main purpose — monitoring multiple loads

components/rbamp is designed to work with a group of modules on a single I²C bus at once, rather than to control a single device. The canonical scenario is a main module at the mains inlet plus N modules on individual loads, all on one bus, driven by one ESP32. The library provides a fleet-handle: a single object through which you scan the bus, poll every module in one call, obtain the total consumed power and the "inlet − Σ(loads)" balance, catch per-module errors, and — when needed — synchronize period snapshots with a broadcast command.

Multi-channel modules are also supported — the current-only I2 / I3 (2 / 3 current channels) and the voltage-equipped UI2 / UI3 / UI5 / UI7 (2 / 3 / 5 / 7 current channels, with power, PF and Wh per channel). Each channel has its own CT sensor model. This is typical for a sub-panel where a single installation point monitors several feeders: one module gives a per-channel breakdown without a separate module on each.

Important architectural detail. Power and Wh need a UI variant; a "mains minus sum of loads" balance needs a UI module on every load. The I-variants (I1/I2/I3) measure current only — they have no voltage, active power, or PF. Active energy (Wh) and power are computed only on the UI-variants (which have a voltage front-end). In the canonical deployment the "mains-meter" role (total energy) is filled by a single UI1 at the mains inlet, while the sub-meter role (per-load current detail) is filled by I2/I3 modules (or by UI2 / UI3 / UI5 / UI7 when power and Wh are needed per load).

Working with a single module is the minimal case of this same library: rbamp_handle_t is the building-block that the fleet is built on top of. If you have one module on the bus, you use that same handle directly — no fleet-API needed.


The 80% scenario — mains + N sub-loads

One master on a shared I2C bus with a mains module at the feed and sub-load modules on individual branches, one clamp per module.

  • 1 module at the inlet (mains) — total consumption and grid quality.
  • N modules on individual loads — per-channel accounting.
  • Multi-channel modules fit this case too: one UI2 / UI3 / UI5 / UI7 (or I2 / I3) can meter several loads, each on its own channel — N modules do not have to mean N loads.
  • A single fleet call rbamp_fleet_poll_all() polls everything; the balance mains − Σ(sub_loads) reveals the "rest" (background consumption, unaccounted loads, leakage).
  • One shared master timestamp → correct Wh accounting with no inter-module drift (see 02_tiers.md and the section on the master wall-clock in 09_api_reference.md).

For details, see chapter 06 · Examples, scenario 1 ("Mains + N sub-loads — the 80% canon"). For the API, see chapter 09 · API Reference, the "Fleet manager" section.


What rbAmp measures

Quantity Type Range
RMS voltage U_rms float, V 0…300 V
Peak voltage U_peak float, V 0…450 V
RMS current I_rms float, A depends on the selected sensor — see 03_sensor_selection.md
Peak current I_peak float, A depends on the selected sensor
Active power P (signed in RT) float, W depends on the selected sensor
Power factor PF float −1…+1
Mains frequency uint8, Hz 50 / 60 Hz (detected)
P averaged over a period float, W same as P

The RT value of active power P is always signed on any module line (negative = export to the grid). The behavior of the period-averaged value (avg_p[ch] in rbamp_period_snapshot_t) depends on the module line — see the "Module lines" section below and 02_tiers.md.


Wiring

The module connects to the master with four wires on the LV side. The mains side (L/N voltage input and the CT clamp) is galvanically isolated from it; see 04 · Wiring, "Mains and CT connection" (mains voltage can kill — read the warning there first).

Wire Purpose
VCC +5 V (4.5..5.5 V), ~15 mA, peak ~25 mA. On-board regulator and filtering
GND common with the master (required)
SDA, SCL I²C, 3.3 V logic, 5 V-tolerant. Built-in 4.7 kΩ pull-ups to 3.3 V
DRDY optional, open-drain LOW ~10 µs every ~100 ms

The default address is 0x50 (7-bit, settable range 0x08..0x77), the recommended speed is 50 kHz on ESP32 (see the section on the retry+sanity discipline below). Cold start until the first valid measurement is ~250 ms.

The full rules (bus length, pull-up recommendations on a multi-module bus, wiring diagrams for the various ESP32 targets) are in chapter 04 · Wiring.


Module lines (quick cheat sheet)

BASIC and STANDARD (STD) modules are shipping. BASIC follows the logic of a classic mechanical meter — one-way (consumption-only) accounting; STD keeps signed energy counters:

Tier RT power P Per-period accumulator avg_p[ch] Component Wh counter
BASIC signed (negative = export to the grid, visible in real time) each 100 ms window of average P is clamped to max(P, 0) before being added to the period accumulator monotonic — consumption-only accounting
STANDARD (STD) signed; also reactive and apparent power snapshot banks, or counter differences — export is kept (import and export counted separately) signed net value (negative = net export)

For details, see chapter 02 · Module lines. At the component level the same rbamp_handle_t handle is used regardless of tier — rbamp_begin() detects the module line (rbamp_line()); the differences show up in the values the module returns and in the extra rbamp_std_* calls an STD module offers.

Bidirectional accounting on BASIC: rbamp_energy_wh(dev, ch) on the BASIC tier gives consumption only. If you need to account for export separately, sample the RT power rbamp_read_power(dev, 0, &p) at ~10 Hz and split the positive and negative samples into two accumulator variables yourself. See the example in 06_examples.md (Scenario 9, "Bidirectional metering on the master side").


What this component does

Timeline of back-to-back 100 ms measurement windows, the optional data-ready pulses and a master-triggered period snapshot. Its main job is to hide the protocol exchange and relieve the user application of the routine of dealing with registers, byte order, and post-command settle times. Additionally, the component computes energy (Wh) — the module returns only the period-averaged power, and the integration is done by the master via esp_timer_get_time().

The component also takes care of the period accounting: it takes a snapshot, waits for the module to settle, checks that the snapshot is valid, and integrates Wh against the master clock (rbamp_read_period_snapshot() and rbamp_energy_wh(), see 05 · Quickstart Step 5). The register-level comparison ("without the component"), the architecture diagram, the interaction diagrams and the mapping table are in 09 · API Reference, appendix "Under the hood".


Logging and Kconfig

Unlike the Arduino library, where the log stream is configured at runtime (setLogStream(&Serial)), here the standard ESP-IDF pattern is used: the component logs under the "rbamp" tag via esp_log. The log level is compiled in via the Kconfig choice CONFIG_RBAMP_LOG_LEVEL_* (NONE / ERROR / WARN / INFO / DEBUG, INFO by default). At NONE the log strings are removed from the binary entirely.

The runtime filter works too (via esp_log_level_set("rbamp", ...)), but it is capped from above by the compile-time level.

Six CONFIG_RBAMP_* symbols are available in idf.py menuconfig → Component config → rbAmp client:

Symbol Purpose Default
CONFIG_RBAMP_DEFAULT_I2C_FREQ_HZ SCL frequency for the shared bus 50000 (50 kHz)
CONFIG_RBAMP_I2C_TIMEOUT_MS transmit/receive timeout 100 ms
CONFIG_RBAMP_NACK_RETRY_ATTEMPTS retry attempts per single-byte read 3
CONFIG_RBAMP_NACK_RETRY_GAP_MS gap between retry attempts 5 ms
CONFIG_RBAMP_DISABLE_ENERGY remove the Wh accumulator from the build n
CONFIG_RBAMP_LOG_LEVEL_* compile-time level of log strings INFO

For more detail, see 09 · API Reference, the "Compile-time configuration" section.


What's next