02 · Module tiers

The BASIC and STANDARD (STD) module lines side by side: energy on the master for BASIC, on the module for STD.


What a module line is

Check the label on your module; dev.line() prints the line after begin().

rbAmp comes in module lines: BASIC and STANDARD (STD). A module line is a complete pairing of hardware revision and firmware, not a software flag. Moving between module lines requires a physical SKU change, not a firmware update.

From the perspective of the library and your code: one RbAmp class serves both shipping lines. begin() detects whether a module is BASIC or STANDARD (STD) and routes every call internally; the common methods (readVoltage(), readCurrent(), readPower(), readPeriodSnapshot(), energy() …) work on both. The STD line adds calls of its own — reactive and apparent power, per-channel block reads, signed life-time energy counters — see 09 · API reference.


Current status

The BASIC tier and the STANDARD (STD) line are shipping module lines; this library supports both (STANDARD (STD) from library 1.6.0, see the README).

Tier Shipping
BASIC ✅ yes
STANDARD (STD) ✅ yes (library 1.6.0+)

BASIC — entry tier for consumer metering

Hardware

A cost-optimized analog path suited to typical household loads. The module includes an isolated analog front-end, an on-board power regulator, and factory calibration stored in flash.

Firmware behavior

The logic of a classic mechanical disk meter — the count only moves forward; export to the grid is not subtracted.

The three "layers" of active-power values behave differently:

Signal Meaning Behavior on BASIC
dev.readPower(ch) instantaneous RT power, updated every ~100 ms signed — a negative value is visible in real time (export)
PERIOD_AVG_P_W (inside readPeriodSnapshot) average power over the period each 100 ms window's average P is clamped to max(P, 0) before being added to the period accumulator
dev.energy().wh(ch) Wh accumulated by the library monotonic — consumption only; export is not counted

In other words: the user sees export in the RT reading, but it is absent from the library's Wh counter on BASIC.

Typical use cases

  • Households without on-site generation (no solar panels, wind turbines, or battery systems)
  • Submeters for purely consuming loads (water heaters, motors, appliances)
  • Building consumption monitoring where bidirectional metering is not required

Bidirectional metering on BASIC (master-side)

Energy accounting on BASIC (consumption on the module, export integrated on the master) and on STANDARD (STD) (import, export and net counters on the module).

If you need to track export to the grid separately on a BASIC module, do it on the master side. The RT power dev.readPower(0) is signed, so:

cpp
double consume_wh = 0.0;
double export_wh  = 0.0;
uint32_t t_prev_ms = millis();
void loop() {
    // Sample RT power at 10 Hz — matches the firmware-commit cadence
    // (100 ms per channel). Faster gives empty repeat reads; slower
    // loses resolution on abrupt load transitions.
    //
    // delay() blocks the loop — incompatible with concurrent work
    // (LCD refresh, MQTT, networking). For sketches with other tasks,
    // replace it with a non-blocking millis() / scheduler pattern.
    delay(100);
    uint32_t t_now_ms = millis();
    float dt_s = (t_now_ms - t_prev_ms) / 1000.0f;
    t_prev_ms = t_now_ms;
    float p = dev.readPower(0);
    if (isnan(p)) return;
    double dwh = (double)p * dt_s / 3600.0;
    if (p >= 0) consume_wh += dwh;
    else        export_wh  += -dwh;
}

A complete working example is in 06_examples.md (the BidirectionalEnergy scenario) and in examples/06_BidirectionalEnergy/.


STANDARD (STD) — bidirectional line

STANDARD (STD) modules are a shipping module line. The library detects them in begin() (dev.line() == RbAmpLine::Std) and uses the same wiring and the same common API as BASIC (see 04 · Wiring).

What the STD line adds

On an STD module with persisted counters, the period/snapshot API and energy come from the module's own counters (older STD images use the module's snapshot banks); the CT model on STD is a label only and sets no gain.

  • Signed energy: import and export are accounted separately. On modules that keep persisted life-time counters, dev.energy() and readPeriodSnapshot() take the module's own figures (wh_net = import − export), and stdReadEnergy() gives the raw counters (Wh, mWh and, on images that provide them, µWh / µvarh).
  • More quantities (on BASIC, reactive power is not exposed by this library): readReactivePower(ch), readApparentPower(ch), stdReadChannel(ch) (I / P / Q / S / PF / peak in one burst), and, when enabled, harmonics-based values (THD, displacement PF).
  • Multi-channel / multi-voltage modules: channel counts come from the module; stdReadVoltage(v), per-phase totals with stdReadTotals(k).
  • Diagnostics and service: stdReadHealth(), module clock, history and event log, identification by UID, firmware update over I²C.

All of this is listed call by call in 09 · API reference § STD line API.

Image dependence. Some STD features depend on the module's image version: micro-resolution energy counters, the starting current for energy, voltage phase angles and the phase sequence need a module image version of at least 0x0001007B (dev.stdReadImageVersion()); on an older image they are reported as "not available". STD-only calls on a BASIC module return RB_ERR_NOT_IMPLEMENTED.

Typical use cases

  • Homes with rooftop solar generation
  • Homes with wind turbines
  • Battery storage systems
  • Regenerative loads
  • V2G (vehicle-to-grid) EV charging

How to detect the line at runtime

How to tell which module line you own: read the label or call line() after begin().

cpp
if (!dev.begin()) { /* see dev.errorString() */ }
// Product line, detected by begin(): BASIC or STANDARD (STD)
RbAmpLine line = dev.line();          // RbAmpLine::Basic / RbAmpLine::Std
// Firmware version — opaque byte
uint8_t fw = dev.firmwareVersion();
// Presence of a voltage sensor (UI* variants vs I*-only)
bool voltage_hw = dev.hasVoltageHw();
// Number of current channels
uint8_t channels = dev.channels();
// Full SKU — variant byte (REG_HW_VARIANT)
RbAmpVariant variant = dev.readVariant();   // UI1, UI2, UI3, I1, I2, I3, UI5, UI7 …

Note: line() tells you BASIC or STANDARD (STD). The other indicators (firmware version, channel count, voltage sensor, SKU) describe the hardware. The SKU label on the module's enclosure remains the source of truth for the product.


Where tier-dependent items are flagged in the documentation

Throughout the library text and the canonical documentation, tier-dependent features are flagged explicitly, for example:

STANDARD (STD) only — this is not available on a BASIC module.

Or, conversely, BASIC-specific behavior:

BASIC: the dev.energy().wh(ch) counter is monotonic — export to the grid is not counted. For bidirectional metering, see the BidirectionalEnergy example or use a STANDARD (STD) module.


What's next


Source & issues: rb-amp/rbamp-arduino · this page in the repo: docs/02_tiers.md (v1.6.2)