Skip to Content

Project kits

Energy monitor kits — what to buy to monitor your house, flat or workshop

You know what you want to see — what the solar sells, what the heat pump costs, which machine eats the input — but not which parts to order. Each kit is one project: the meters, modules and hub, plus the clamps, rated for your breakers. How to build it is on rbgrid.io.

Energy monitor kit for a solar house that exports (single-phase, with a car charger)

One total on the meter mixes what you bought with what you sold, and the car charger hides in it. With this kit you see the supply, the inverter line and the circuits apart, with export valued at your sell price.

  • 2 × STD-UI1, 60 A kit — on the supply and on the inverter line, each with its calibrated sensor
  • 1 × Basic UI5 for SCT-013 — five current channels; this build uses four, one stays spare
  • 4 × SCT-013 voltage-output clamps — choose each rating by its circuit's breaker
  • Hub — an ESP32 with PSRAM and 16 MB flash: an ESP32-WROVER, or an ESP32-S3 on the N16R8 module. One you have, or one you buy (not in the kit)

From $53.79 for the meters and modules; SCT-013 clamps from $3.59 each; the hub is extra.

Build this kit in the configurator →

How to build it → rbgrid.io

3-phase energy monitor kit for a house with a heat pump and an EV charger

The bill says how much the house used, not what the heat pump and the charger cost in each tariff zone. With this kit you see the three-phase input and both big loads. The STD-U3I3 counts import and export separately at the supply, three phases live — ready if solar comes later.

  • 1 × STD-U3I3, 60 A kit — on the three-phase input, with its calibrated sensors
  • 3 × Basic UI3 for SCT-013 — one per phase: a Basic module measures only the circuits of its own phase
  • 7 × SCT-013 voltage-output clamps — choose each rating by its circuit's breaker
  • Hub — an ESP32 with PSRAM and 16 MB flash: an ESP32-WROVER, or an ESP32-S3 on the N16R8 module. One you have, or one you buy (not in the kit)

From $86.87 for the meters and modules; SCT-013 clamps from $3.59 each; the hub is extra.

How to build it → rbgrid.io

Energy monitor kit for a flat with a day/night tariff

A day/night tariff only pays off if you know what runs when. With this kit you see the supply and five circuits, each in its tariff zone.

  • 1 × STD-UI1, 60 A kit — on the supply, with its calibrated sensor
  • 1 × Basic UI5 for SCT-013 — five current channels
  • 5 × SCT-013 voltage-output clamps — choose each rating by its circuit's breaker
  • Hub — an ESP32 with PSRAM and 16 MB flash: an ESP32-WROVER, or an ESP32-S3 on the N16R8 module. One you have, or one you buy (not in the kit)

From $33.89 for the meters and modules; SCT-013 clamps from $3.59 each; the hub is extra.

How to build it → rbgrid.io

3-phase energy monitor kit for a workshop

You don't know which machine runs, what the compressor costs, or how close the workshop gets to its input limit. With this kit you see the three-phase input and five circuits.

  • 1 × STD-U3I3, 60 A kit — on the three-phase input, with its calibrated sensors
  • 1 × Basic UI1 and 2 × Basic UI3 for SCT-013 — one per phase: a Basic module measures only the circuits of its own phase
  • 5 × SCT-013 voltage-output clamps — choose each rating by its circuit's breaker
  • Hub — an ESP32 with PSRAM and 16 MB flash: an ESP32-WROVER, or an ESP32-S3 on the N16R8 module. One you have, or one you buy (not in the kit)

From $81.87 for the meters and modules; SCT-013 clamps from $3.59 each; the hub is extra.

How to build it → rbgrid.io

Energy monitor kit for a car park with three EV chargers

Three chargers on one supply: how close do they get to its capacity? With this kit you see the supply, the building, the lighting and each charger.

  • 1 × STD-UI1, 100 A kit — on the supply, with its calibrated sensor
  • 1 × Basic UI5 for SCT-013 — five current channels
  • 5 × SCT-013 voltage-output clamps — choose each rating by its circuit's breaker
  • Hub — an ESP32 with PSRAM and 16 MB flash: an ESP32-WROVER, or an ESP32-S3 on the N16R8 module. One you have, or one you buy (not in the kit)

From $33.89 for the meters and modules; SCT-013 clamps from $3.59 each; the hub is extra.

How to build it → rbgrid.io

Energy monitor kit for an EV charger on a garage board

The bill went up, and nothing tells you how much of it was the car. This kit meters a single-phase charger's circuit at the garage board. A second ESP32 next to it, running RBgrid's node firmware, reports to the RBgrid hub in the house, so you see what the car took and what it cost at the hour it charged.

Not included: the voltage connection. L and N go to the module's terminals, with a fuse in L, on the same phase as the clamped circuit. This is mains wiring: have a qualified electrician do it. The clamp itself goes around one insulated conductor and touches nothing live.

Not included: the ESP32. Use an original ESP32 board (not S2, S3 or C3) with 4 MB flash and no PSRAM. It is flashed over USB, so mount it where a laptop cable reaches.

From $7.58 with a Basic module and one clamp; from $19.90 with an STD meter, its calibrated sensor included.

  • 1 × Basic UI1 for SCT-013 — measures voltage and current, so it keeps energy records
  • 1 × SCT-013 voltage-output clamp — 50 A for a 32 A charger, 60 A for a 40–48 A charger
  • or, instead of both: 1 × STD-UI1, 60 A kit, with its calibrated sensor
  • Your RBgrid hub — the one already in the house (not in the kit)

Meter the charger's circuit or the garage sub-panel, not both.

How to set it up → rbgrid.io

Energy monitor kit for a water heater on a shared circuit

The water heater shares a circuit with other loads, so nothing tells you how much of it is the tank. This kit meters a single-phase water heater alone, at the tank. A second ESP32 next to it, running RBgrid's node firmware, reports to the RBgrid hub in the house.

Not included: the voltage connection. L and N go to the module's terminals, with a fuse in L, on the same phase as the clamped circuit. This is mains wiring: have a qualified electrician do it. The clamp itself goes around one insulated conductor and touches nothing live.

Not included: the ESP32. Use an original ESP32 board (not S2, S3 or C3) with 4 MB flash and no PSRAM. It is flashed over USB, so mount it where a laptop cable reaches.

From $7.58 with a Basic module and one clamp; from $19.90 with an STD meter, its calibrated sensor included.

  • 1 × Basic UI1 for SCT-013 — measures voltage and current, so it keeps energy records
  • 1 × SCT-013 voltage-output clamp — choose the rating by the circuit's breaker
  • or, instead of both: 1 × STD-UI1, 60 A kit, with its calibrated sensor
  • Your RBgrid hub — the one already in the house (not in the kit)

Meter the heater or the circuit it shares, not both.

How to set it up → rbgrid.io

Energy monitor kit for a well pump or a pool pump

The nameplate won't tell you what the pump uses, or how often it starts. This kit meters a single-phase pump at the well house or the equipment pad. A second ESP32 next to it, running RBgrid's node firmware, reports to the RBgrid hub in the house.

Not included: the voltage connection. L and N go to the module's terminals, with a fuse in L, on the same phase as the clamped circuit. This is mains wiring: have a qualified electrician do it. The clamp itself goes around one insulated conductor and touches nothing live.

Not included: the ESP32. Use an original ESP32 board (not S2, S3 or C3) with 4 MB flash and no PSRAM. It is flashed over USB, so mount it where a laptop cable reaches.

From $7.58 with a Basic module and one clamp; from $19.90 with an STD meter, its calibrated sensor included.

  • 1 × Basic UI1 for SCT-013 — measures voltage and current, so it keeps energy records
  • 1 × SCT-013 voltage-output clamp — choose the rating by the circuit's breaker
  • or, instead of both: 1 × STD-UI1, 60 A kit, with its calibrated sensor
  • Your RBgrid hub — the one already in the house (not in the kit)

If the pump's circuit starts at a board your hub already reaches, one clamp there does the job, with no node.

How to set it up → rbgrid.io: well pump · pool pump

Your clamps follow your breakers

For each circuit, take the smallest SCT-013 rating at or above its breaker. The STD meters come with their own calibrated sensors, so the supply needs no clamp.

Safety. The measurement inputs connect to mains. For work inside an electrical panel, call a qualified electrician.

A different panel?

Pick what you want to see, and the configurator lists the modules and clamps.