00 · Overview


What is rbAmp

rbAmp is a compact hardware module for measurement of AC mains parameters over an I2C interface. It ships with factory-stored calibration.

From the integrator's point of view, rbAmp behaves like a standard I2C slave: apply power, read registers — receive ready-to-use physical-unit values (volts, amperes, watts). No signal processing is required on the master side. Block diagram of an rbAmp module connected to a master over I2C, from the mains-side sensors to the registers the master reads.


What it measures

BASIC reports the quantities below as floating-point values in base units. The STD line reports its quantities, with on-module energy counters, in the STD documentation.

Quantity BASIC
RMS voltage, U_rms float32, V
Peak voltage, U_peak float32, V
RMS current, I_rms float32, A
Peak current, I_peak float32, A
Active power, P float32, W, signed
Reactive power, Q float32, var, unsigned (≥ 0)
Power factor, PF float32, −1…+1
Line frequency u8, Hz: 50 or 60 (detected, not measured)
Average power over a period float32, W; one snapshot (average and peak P)
Energy not kept on the module — the host (library) integrates it

Accuracy is not part of this table: for BASIC with an SCT-013 sensor see the SCT-013 characteristics table below; specifications of individual modules are given with the model descriptions. The BASIC register map is in realtime-polling.md, period-metering.md and api-reference.md.

Current-channel accuracy with SCT-013 sensors

BASIC modules (SCT-UI series) with your own SCT-013 sensor — resistive load, measured at 50 Hz. (Modules with a factory-paired CT sensor, and STD modules, are specified separately — this table does not apply to them.)

Characteristic SCT-013-005 SCT-013-010 SCT-013-020 SCT-013-030 SCT-013-050 SCT-013-060 SCT-013-100
Detectable floor (the reading with no load) ~3 mA 6–9 mA ~10 mA ~13 mA ~25 mA ~30 mA ~60 mA
Readable floor (error ≤ 10 %; 0.5 % of rating) 25 mA 50 mA 0.10 A 0.15 A 0.25 A 0.30 A 0.50 A
Class near the floor, UI1 / UI2 / UI3 (±1 % of the average, from ~0.7 % of rating) from 35 mA from 70 mA from 0.14 A from 0.21 A from 0.35 A from 0.42 A from 0.70 A
Class near the floor, UI5 / UI7 (±0.5 %, from 2 % of rating) from 0.10 A from 0.20 A from 0.40 A from 0.60 A from 1.0 A from 1.2 A from 2.0 A
Class in the working range (5–100 % of rating, of the average) ≤ 0.5 % 0.16–0.35 % ≤ 0.5 % 0.53 % ≤ 0.5 % ≤ 0.5 % 0.47 %
Tolerance of the sensor unit (added on top of the class) ≤ 0.8 % 0.5–1.0 % 0.8 % 1.2 % 0.7 % 0.3–0.4 % 0.45 %
Step of one instantaneous value 4.1 mA 8.1 mA 16 mA 24 mA 41 mA 49 mA 83 mA
Top of the range (clipping, sine wave) ~6.0 A 11.9 A ~24 A 35 A ~60 A ~72 A ~117 A

Source: verified in multiple bench laboratory tests. Note that real SCT-013 sensors have an actual error of about 1 %, and it can grow with time or with temperature. If you need good measurement quality at small currents, choose a sensor with a smaller rating.

  • Step of one instantaneous value is about 0.08 % of the rating. The RMS reading is computed over the whole 100 ms window and returned as a fractional number, so it is finer than the step: for example, with the 5 A sensor the no-load reading is ~3 mA although the step is 4.1 mA. The real resolution is limited by noise, not by the step.
  • Near the floor: a single reading (one 100 ms window) at 1 % of the rating is noisy by 0.6–2 %. The average over a period and the energy stay within the class shown in the table.
  • UI5 / UI7 below 2 % of the rating: the spread between modules is up to ±5 %, so for these modules the class near the floor starts at 2 % of the rating.
  • "Average" = the average of several 100 ms measurement windows, as used for energy and average power.
  • Clipping is a property of the SCT-013 sensor (its output level at rated current); stay below the rating for reliable readings.
  • Changing the sensor model is writing the model code to the module — no recalibration step.

Applications

  • Tariff metering — energy accounting in 1-min, 15-min, 1-hour, daily, monthly, or yearly intervals
  • Smart home — whole-house consumption monitoring, per-load sub-metering, generation tracking
  • Load control — feedback signal for power-regulating devices (water heaters, resistive loads, inverters)
  • Energy balancing — separate accounting of consumption and generation in homes with solar
  • Grid quality monitoring — both on the consumer side and on the utility side

Module variants

Current BASIC product line: SCT-UI1, SCT-UI2, SCT-UI3, SCT-UI5, SCT-UI7, SCT-I1, SCT-I2, SCT-I3. In the code, UIn means one voltage input and n current channels; In means n current channels only. The modules are supplied without a sensor; characteristics for each SCT-013 rating are in the SCT-013 table. Other module lines have a different composition; a table for each line will be added here as it goes on sale.

BASIC — for SCT-013 type sensors

Module U I channels P When to choose
SCT-UI1 yes 1 yes single accounting point — whole-house meter, boiler, single inverter
SCT-UI2 yes 2 yes two sub-meters on one phase (lights + outlets, generation + consumption)
SCT-UI3 yes 3 yes three flows on one phase
SCT-UI5 / SCT-UI7 yes 5 / 7 yes high-channel-count phase monitoring (large panels, lab benches)
SCT-I1 no 1 no current-only monitor (master computes P with its own U source)
SCT-I2 no 2 no two-channel current monitor
SCT-I3 no 3 no three-channel current monitor

BASIC — with factory-paired CT clamps (CT series)

Module U I channels P When to choose
CT-UI1 yes 1 yes one measuring point with a ready, calibrated clamp
CT-UI2 yes 2 yes two sub-meters on one phase
CT-UI3 yes 3 yes three flows on one phase
CT-UI5 / CT-UI7 yes 5 / 7 yes high-channel-count per-phase metering

A CT-series module is delivered with a current clamp on every channel. The clamp and the channel are calibrated together at the factory and marked with the channel number: there is nothing to select or configure. Clamp ratings are 1, 5, 10, 20, 30, 50 or 100 A. The voltage input is the same as on the SCT series. See CT-series modules: start-up without configuration.

On I-only variants, active power is not computed (P_real = 0), and PERIOD_AVG_P_W returns 0. The master must either provide its own voltage source for power calculation, or use the current data alone.


Product tiers

rbAmp is offered in two product tiers. Each tier is a complete combination of hardware revision and firmware — not a firmware-only flag. Moving between tiers requires a physical SKU change, not a firmware update.

The BASIC and STANDARD (STD) rbAmp module lines side by side.

BASIC — entry-level product line

  • Hardware: cost-optimized analog front-end suitable for typical residential loads.
  • Firmware: unidirectional consumption metering. The per-period accumulator clamps each per-window active-power sample to zero before integrating: only positive (consumed) energy is counted, mirroring a classical mechanical disc meter that only spins forward.
  • PERIOD_AVG_P_W is always ≥ 0; reverse-flow events are dropped from the period accumulator.
  • Use cases: households without on-site generation; sub-metering of pure consumers (heaters, motors, appliances).

STD — a separate product line

STD is a separate product line: single- and three-phase modules with energy counters on the module and Modbus RTU. It has its own register map and its own documentation — see the STD documentation.

Where the tier shows up in this documentation

This documentation describes the BASIC 8-bit register map (0x00..0xCF). STD modules use a different, 16-bit register map and are documented in the STD documentation; on STD these functions work differently.


Key features

  • I²C slave: 50 kHz on ESP32 and ESP8266 hosts (ESP-IDF driver limitation), 100 kHz on other hosts; 400 kHz is not recommended.
  • Address: 7-bit 0x50 by default, reprovisionable to the 0x08..0x77 range via two-phase commit (see initialization.md).
  • DATA_READY (DRDY): optional open-drain pin, ~10 µs LOW pulse every measurement window (~100 ms from v1.2; 200 ms before), marks the moment when RT registers are coherent.
  • Atomic period snapshot: command 0x27 freezes the per-period averaged power; one write closes and opens — no dropped or duplicated samples at the boundary.
  • General-Call broadcast snapshot: address 0x00 reserved for simultaneous snapshot on all modules sharing a bus. Opt-in per module via FLEET_CONFIG.bit0 (default OFF). When OFF, GC frame NACKs at the bus level — masters detect this and fall back to per-module sequential snapshot (skew on 50 kHz bus is ~1 ms × N, ≪ 0.03% of 60 s period). See period-metering.md for enable sequence and frame format.
  • Master-side wall-clock: energy is computed master-side as avg_P × dt_master; the chip-side period timestamp register (0xEC) is diagnostic-only (can undercount up to ~30% under load — by design). Eliminates per-module crystal drift in multi-module systems.
  • Calibration in flash: factory calibration is stored on the module; no user calibration is required. On BASIC SCT-series modules the master writes only SENSOR_CLASS and CT_MODEL per channel for the connected SCT-013 sensor. On CT-series modules the host writes nothing — see start-up without configuration.
  • Auto-configuration: the module starts measuring immediately after power-on (~250 ms to the first valid result, ~700 ms additional for first persistence write).

What rbAmp does not do

  • Does not integrate energy (Wh) internally — energy accumulation is the master's responsibility (see period-metering.md)
  • Does not drive loads, contain automation logic, or run programmable rules
  • Has no built-in display

Next